Services
The FluidCom™ is a fully automatic chemical injection controller for Scale Inhibitor, Corrosion Inhibitor, Emulsion Breaker, Antifoam and more.
Application Features
Its unique patented technology is considered a worldwide game changer, enabling significant CAPEX and OPEX savings.
By ensuring reliable and accurate chemical dosage, the end users obtain a controlled and efficient use of production chemicals by optimizing the oil and gas production, improve water quality and secures system integrity.
Features
The FluidCom™ is a flow control valve comprising down to following:
All-in-one unit
✓ Flow Control Valve
✓ Actuator
✓ Flowmeter
✓ Controller
Stable and reliable injection rate – significant reduction in OPEX for operations
Reduced size and weight
Flow rate independent of variations in pressure, temperature, viscosity, and specific gravity
Self cleaning – No regular maintenance required, hence improved HSE
Enables real-time control and monitoring/digitization
Stable injection rate over time independent of changes in temperature, pressure, viscosity, and specific gravity of the fluid
Benefit of using FluidCom™
FluidCom has achieved:
Stable chemical injection rate which minimizes overdosing and under dosing without frequent site visit to re-adjust the injection rate.
A virtually maintenance-free operation due to using minimal mechanical moving parts and self-cleaning capabilities.
The ability to adjust the injection rate setpoint locally and remotely.
The ability to view the flowrate locally and remotely.
Unique Self-cleaning Capability
If clogging is identified, FluidCom™ will automatically increase the flow rate opening the outlet valve fully to allow for debris/deposits to be flushed over the valve seat.
The Self-cleaning performance of FluidCom™ resolves the most common problem of plugging in a conventional valve which leads to periodic mechanical maintenance.
Fluidcom™ valve feature 2 modes
of operation, Auto and Manual.
Manual mode is the most rugged mode of operation as valve runs only by a fix power setting given by operator at local unit display or by remotely setting 0-100% ≈ (0-100W).
Manual mode is the only self-balanced flow control i.e cooling against a fix heater setting. This mode is the only mode that allows flow controlling below 0.6 or 0.3 l/h to 0.1 l/h.
Manual mode can also be tested/calibrated to determine correct power settings to desired flow rates.
Auto mode enables measuring flow rates and tune in to preset and calibrated flow rates, this by controlling the power to the heater based upon conditions received by inbuilt temperature sensors.
Auto mode is the only mode to allows 8 off calibrated fluids pre saved to internal valve memory.